On our website you will find the calibration and setting of all machines, the parameters of the machine mentioned by us. If you put it in your weighing scale machine then it will give you the right weight.
हमारी वेबसाइट पर आपको सभी मशीनों का कैलिब्रेशन और सेटिंग मिलेगी. हमारे द्वारा बताए गए मशीन के पैरामीटर अगर आप अपने वजन पैमाने की मशीन में डालेंगे तो वह आपको सही तोल देगी.
analytical weighing Scale, 200 gm weighing Balance,500 gm weighing Balances ,1 kg weighing scale , 2 kg weighing balance , 5 kg weighing scale, 10 kg weighing machine, 20 kg weighing scale, 30 kg weighing machine ,40 kg weighing balance , 50 kg weighing scale, 100 kg weighing machine , 150 kg platform weighing scale, 200 kg platform weighing scale, 300 kg platform weighing scale, 500 kg platform weighing machine, 1000 kg weighing machine and all company weighing scale calibration available.
1. Any One Button Press With Out TARE
2. Press that button Then Switch ON , The HELP written on the display. The Common First Button Of Calibration
3.Next Any Button Press Without TARE And (Common HELP)
4.Press that button Then Switch ON , The (Lo battery) written on the display. The Common Second Button Of Calibration
5.Put a Cast Iron Weight Of 5 KG On Your Weighing scale Plate form.
6.And then we have to press the button that showed the HELP in the display and also press the
( Lo battery)
7.Display Show ENTER Then Two Time Press ZERO In 3 Second Gap.
8.Calibration Done Display Show On 5.000 Kg .
2. All Gold-tech Weighing Scale Calibration
When the machine is ON, the display will show 0000. There should be no weight or any
material in the pan. If the display does not show 0000 , then press the tare key to bring
the scale to 0000.
Then press both "Func" & “Tare” key , display appears “CAL” after few seconds
required calibration value appears on display .(CAL will appear only if calibration is
enabled . to enable calibration read FUNCTIONS> 0.000 For 30.000 Kg .
• Put the weight of 30 kg
• Press the tare switch
• There is display of 30.000
• Now your machine is ready for use.
And there after it will show all zeros with the appropriate decimal point and “busy”pin
goes off.
The scale is now ready for use.
3. CAS SW Calibration
Calibration Pressing and holding calibration switch press
[POWER] key to go to calibration mode.
User can move to other mode by using [ZERO] key in the calibration mode.
User also moves to other sub-modes for each mode by using [TARE] key.
Please simply follow below procedure to move to other mode.
Calibration Mode: Pressing and holding "Calibration Switch" press [POWER] key.
It displays "CAL-0" after "CAL", and it blinks the version of scale three times.
Selecting menu: press [TARE].ENTER(Setting) Tare Key
4. Essae SI-810 Weighing Scale Calibration
Essae Weighing Scale Calibration And Other Function Setting.
Step: Go To Machine Menu Setting
Screen Show Down Button Below Press More then Show On display Setting
Press Enter And Press Key Down Display Show Calibration
Press Enter Display Show Password 2507
Press Zero Cal Visible Pass Put the weight On Platform
Display Show Weight Clear And Feed
Press Span Cal Calibration done And Press QUIT